Make Up Air
|
|
Maintaining air quality is an issue that all industries are faced with in today's industrial marketplace. Exhaust from equipment such as forklifts is a common problem. Stricter OSHA regulations have forced companies to implement air management plans. Our air management systems allow you to introduce outside air into your building while heating, cooling or filtering the air. However in the middle of winter, exhausting air and then introducing fresh air can be an expensive undertaking because the fresh outside air must be reheated to maintain comfortable inside air temperatures. This is where our 80/20 air management systems excel. When dangerous exhaust fumes in factories are non-existent, such as on the weekends or at night, our systems can be set up to simply heat the inside air, without exhausting any inside air. This feature saves you money because reheating inside air costs less than having to heat the colder outside air.
The versatility of these air management systems has fueled the explosive growth in this segment of our product line. With over 45 years of experience, we can design systems that meet all of your needs. For example, we commonly design systems for auto body repair shops. These air management systems are used in the actual painting process to filter the air and then cure the paint using high temperature heat. Other recent applications include designing an air management system for a regional truck repair facility that not only exhausted dangerous carbon monoxide fumes, but also cooled the inside air to provide a more friendly work environment for the diesel truck mechanics.
The possibilities of this equipment are limitless. Please feel free to call us with your air quality issues. Using our diverse industry experience, we can provide cost effective solutions.
* Prices do not include sales tax or freight. Quantity discounts may apply.
| Rupp Air Management Systems |
| RAMs - Direct Fired Gas Horizontal Heaters |
RUPP Air Management Systems replace 100% of exhausted air or heat the space with a minimum
introduction of fresh air. By introducing fresh heated air, make-up air systems eliminate
drafts, stale air and temperature stratification, and create positive building pressure
while maintaining proper comfort levels.
RUPP Air Management Systems, with direct-fired gas heateres, offer 100% fuel efficiency.
In addition, each RUPP unit has a turndown ratio of 30:1. That means replacement air is
delivered at a constant temperature regardless of outside temperatures.
Packaged for easy field installation, our control panels offer smooth field wiring with
terminal strips - built in accordance with UL 508.
|
| Item # |
Description |
* Price |
| RUPP-RAM |
800-92,000 CFM 100% Make-Up Air |
Call For Pricing |
| RUPP-RAM-M |
2,500-92,000 CFM 80/20 System ® |
Call For Pricing |
|
|
| CFAs - Direct Fired Gas Vertical Heaters |
RUPP Air Management Systems replace 100% of exhausted air or heat the space with a minimum
introduction of fresh air. By introducing fresh heated air, make-up air systems eliminate
drafts, stale air and temperature stratification, and create positive building pressure
while maintaining proper comfort levels.
RUPP Air Management Systems, with direct-fired gas heateres, offer 100% fuel efficiency.
In addition, each RUPP unit has a turndown ratio of 30:1. That means replacement air is
delivered at a constant temperature regardless of outside temperatures.
Packaged for easy field installation, our control panels offer smooth field wiring with
terminal strips - built in accordance with UL 508.
|
| Item # |
Description |
* Price |
| RUPP-CFA |
1,200-130,000 CFM 100% Make-Up Air |
Call For Pricing |
| RUPP-CFAM |
2,500-120,000 CFM 80/20 System ® |
Call For Pricing |
|
|
| KIP/Pressure Plus - Direct or Indirect Fired Gas |
An ingenious design that functions both as a traditional, high-efficiency air curtain
and a make up air unit to remedy negative pressure problems in loading docks and adjacent
areas. With its optional 80/20 feature, the units can also provide up to 2,750,000 BTU/H of
space heating and thus fulfill three separate functions for the installation cost of
just one unit.
37 models for doors from 3 to 16 feet wide and up to 20 feet high.
Product Options:
- Direct or Indirect Fired Gas
- Steam, Hot Water, Electric
- 3,499 thru 24,250 CFM
- 264,000 thru 3,142,000 BTU/H
- DX or Chilled Water Cooling
- Pre-plumbed and Pre-wired
Product Features:
- Low energy costs
- Certified performance ratings based on AMCA Publication 211
- Extremely quiet operation
- 2-year warranty
|
| Item # |
Description |
* Price |
| All Models |
|
Call For Pricing |
|
|
| KCF - Indirect Fired Gas or Oil |
With their unique 15:1 turndown burners and negative pressure heat exchangers,
this line is an ideal solution for indirect fired applications which require any
combination of heating, ventilating and make up air functions.
Unlike traditional burners which only modulate down to 40% of capacity, these 15:1
turndown units expand the modulation parameters to within 6% of capacity for vastly
improved comfort and efficiency. The negative pressure heat exchanger design eliminates
the possibility of any combustion gases ever contaminating the supply air.
Horizontal and vertical, indoor and outdoor configurations are available.
Complete filter, damper and hood accessories.
Product Options:
- Indirect Fired Gas or Oil
- 3,858 thru 79,365 CFM 500,000 thru 6,000,000 BTU/H
Product Features:
- Certified 80% Efficient, Negative Pressure, Heat Exchanger
- 15:1 Ratio Turndown Burners
- Cooling Coils for Any Medium
- Pre-plumbed and Pre-wired
- 2-year warranty
|
| Item # |
Description |
* Price |
| All Models |
|
Call For Pricing |
|
|
COPYRIGHT © 2006 Mid-Valley & Industrials Inc. All rights reserved.
|
|